NYC building rules switch on at specific thresholds: unit count, number of stories, gross floor area and the equipment in the building. A typical 50-unit Brooklyn building crosses almost all of them, so it carries far more recurring filings than a brownstone or a small walk-up.
This guide sorts the main rules by what triggers them. It is a map, not a substitute for each law's details. Every row links to the official source and, where we have one, to our full guide on that law. Use it to build a compliance list for your building, then check the details before each filing.
This is general information, not legal advice. Thresholds and dates change, so confirm with the agency or an attorney before you rely on any of them.
The short version: the size matrix
| Trigger | Threshold | What it switches on | Agency |
|---|---|---|---|
| Units | 3+ units (multiple dwelling) | Annual HPD property registration; Local Law 55 allergen duties; lead paint rules in pre-1960 buildings | HPD |
| Units | 6+ units, built 1947–1973 | Generally rent stabilization, with annual DHCR registration | DHCR (HCR) |
| Units | 6+ families (residential) | Annual boiler inspection filing | DOB |
| Units | 9+ units | Janitorial (super) service required | HPD |
| Stories | Higher than 6 stories | Facade inspection every 5 years (FISP / Local Law 11) | DOB |
| Floor area | Over 25,000 gross sq ft | Annual energy benchmarking (LL84), lobby energy grade (LL33), emissions limits (LL97) | DOB / Sustainable Buildings |
| Floor area | Over 50,000 gross sq ft | Energy audit and retro-commissioning every 10 years (LL87) | DOB |
| Equipment | Gas piping (not R-3 one- and two-family) | Gas piping inspection every 4 years (LL152) | DOB |
| Equipment | Elevator | Annual inspection and CAT1 test; CAT5 every 5 years | DOB |
| Equipment | Rooftop drinking water tank | Annual inspection, report by January 15 | Health Department |
| Equipment | Backflow prevention device | Test every 12 months | DEP |
| Facade | Parapet facing the street | Annual parapet observation (LL126) | DOB |
| Everyone | All residential buildings | Heat season and year-round hot water | HPD |
The rest of this guide walks through each trigger.
Triggers based on unit count
3 or more units: a multiple dwelling
Three or more residential units makes a building a multiple dwelling. That is the line for most HPD duties.
- HPD property registration. Owners of multiple dwellings (3+ units) must register every year. HPD's registration page gives a September 1 deadline and a $13 annual fee billed by the Department of Finance. An unregistered building cannot certify violations, request a Code Violation Dismissal or bring a nonpayment case. See our HPD registration guide.
- Indoor allergens (Local Law 55). HPD requires owners of buildings with three or more apartments to inspect units for mold and pests every year and respond to complaints. See our Local Law 55 guide.
- Lead paint (Local Law 1). In multiple dwellings built before 1960, HPD says owners must presume paint is lead-based. Buildings from 1960 to 1978 are covered if the owner knows there is lead paint. The rules add annual notices, inspections where a child under six lives, turnover work, and a one-time test of painted surfaces that HPD says was due by August 2025. See our lead paint compliance guide.
6 or more units: rent stabilization and boilers
- Rent stabilization. In New York City, HCR says rent stabilization generally covers buildings built between 1947 and 1974, plus some newer buildings with tax benefits. The Rent Guidelines Board points owners of rental buildings with six or more units to HCR to confirm status. Stabilized units need an annual DHCR registration. See our rent stabilization guide and DHCR registration walkthrough.
- Boilers. The DOB boiler page requires annual inspection reports for boilers in residential buildings with six or more families, and in commercial and mixed-use buildings. Buildings with five families or fewer are exempt. Reports are due within 14 days of the inspection. See our boiler inspection guide.
9 or more units: a super
The Housing Maintenance Code requires janitorial service in multiple dwellings of nine or more units, with rules on where the janitor lives and how many units one janitor can cover. The text is in the City's published Housing Maintenance Code, Article 13. Our guide to supers, porters and staffing covers the details.
Triggers based on height
Higher than six stories: FISP
The Facade Inspection and Safety Program requires owners of buildings higher than six stories to have exterior walls and appurtenances inspected every five years and to file a technical report. The current cycle is Cycle 10, split into sub-cycles by the last digit of the tax block number. DOB's sub-cycle diagram gives your window. See our FISP / Local Law 11 guide.
Many large Brooklyn walk-ups are five or six stories, which keeps them out of FISP. Elevator buildings of seven stories or more are in it.
Parapets: any height
The annual parapet observation under Local Law 126 has no height floor. DOB applies it to all buildings with parapets fronting the public right-of-way, regardless of height. Detached one- and two-family homes are exempt, as are buildings where a fence or barrier blocks access to the wall. Reports are kept for six years and shown to DOB on request. See our parapet observation guide.
Triggers based on floor area
The energy laws key off gross square footage as recorded by the Department of Finance. Check the City's Covered Buildings List rather than your own estimate.
Over 25,000 gross square feet
- Benchmarking (Local Law 84). DOB covers a building over 25,000 gross square feet, or two or more buildings on one tax lot that together exceed 100,000. Owners report annual energy and water use by May 1.
- Energy grade (Local Law 33). Buildings on the benchmarking list must post an energy grade near each public entrance. DOB issues the label each October 1, and owners must post it within 30 days. See our energy grade guide.
- Emissions limits (Local Law 97). DOB covers a building over 25,000 gross square feet, or two or more buildings on one tax lot that together exceed 50,000. Annual reports are due May 1, and stricter limits start in 2030. Buildings where more than 35% of units are rent regulated may qualify for a separate Article 321 pathway with prescriptive measures instead of an emissions cap. See our Local Law 97 guide.
Note the different combined-lot thresholds: 50,000 for Local Law 97 and 100,000 for benchmarking.
Over 50,000 gross square feet
- Energy audit and retro-commissioning (Local Law 87). DOB requires buildings over 50,000 gross square feet to complete an energy audit and retro-commissioning every ten years. The report is due in the year whose last digit matches the last digit of the tax block number. Our boiler guide explains why this is a separate rule from the annual boiler filing.
Triggers based on equipment
Gas piping (Local Law 152)
DOB requires gas piping inspections at least every four years, scheduled by community district. One- and two-family homes and other R-3 buildings are exempt. The current cycle runs:
| Sub-cycle | Community districts | Cycle 2 | Cycle 3 |
|---|---|---|---|
| A | 1, 3, 10 | 2024 | 2028 |
| B | 2, 5, 7, 13, 18 | 2025 | 2029 |
| C | 4, 6, 8, 9, 16 | 2026 | 2030 |
| D | 11, 12, 14, 15, 17 | 2027 | 2031 |
Buildings in community districts 4, 6, 8, 9 and 16 are due by December 31, 2026. Confirm your building's community district with City Planning before assuming a year. See our Local Law 152 guide.
Elevators
DOB requires an annual periodic inspection and an annual CAT1 no-load test, both between January 1 and December 31. A CAT5 full-load test is due within five years of the last one. The inspecting agency cannot be affiliated with your maintenance company. See our elevator inspection guide and the 2027 elevator deadline.
Rooftop water tanks
If the building has a drinking water tank, the Health Department requires an annual inspection and water sampling by a qualified inspector. The report is due by January 15 of the following year. See our water tank guide.
Backflow prevention devices
DEP requires many properties to install a backflow device, including those with multiple water service lines and many commercial uses. Devices must be tested every 12 months by a certified tester, with the form signed by a Licensed Master Plumber. A missed test can bring fines or a water shutoff. See our backflow guide.
Rules that apply to every residential building
Some duties have no threshold at all. The biggest is heat and hot water. HPD sets the heat season from October 1 to May 31. During the day, if it is below 55°F outside, apartments must be at least 68°F. At night, they must be at least 62°F. Hot water must be at least 120°F all year. See our heat and hot water requirements.
Renovation can also create new duties. A major alteration can trigger a sprinkler retrofit; see when renovation triggers sprinklers.
How a typical 50-unit Brooklyn building lines up
Take a common profile as a rough illustration: a pre-war Brooklyn building with about 50 rental units, five or six stories, and somewhere around 40,000 to 60,000 gross square feet. Your building's numbers will differ, so check its own records.
| Rule | Applies? | Why |
|---|---|---|
| HPD registration | Yes | 3+ units |
| Local Law 55 allergens | Yes | 3+ units |
| Lead paint (Local Law 1) | Yes | Pre-1960 multiple dwelling |
| Rent stabilization / DHCR | Check every unit | 6+ units; status depends on build date, history and tax benefits |
| Boiler inspection | Yes | 6+ families |
| Janitorial service | Yes | 9+ units |
| FISP | Usually no | Not higher than six stories |
| Parapet observation | Yes, if it has a street-facing parapet | No height floor |
| LL84, LL33, LL97 | Yes | Over 25,000 gross sq ft |
| LL87 energy audit | Depends | Only if over 50,000 gross sq ft |
| Gas piping (LL152) | Yes | Not R-3 |
| Elevator | Only if it has one | Equipment |
| Water tank | Only if it has one | Equipment |
| Backflow | Depends on DEP requirements | Equipment and use |
That is eight to twelve recurring obligations for one address, run by at least five agencies, each with its own portal and calendar. Many pre-war buildings still contain regulated units. Confirm each unit's status through DHCR rent histories rather than the construction date alone; our rent roll audit guide shows how.
The size of the obligation list is one reason larger buildings need a manager with a real compliance system. One missed annual filing can cost more than a year of careful tracking.
How to build your building's list
- Pull the building's records. Use HPD Online for registration and violations, and DOB NOW and BIS for filings and equipment. See our DOB NOW guide.
- Get the DOF gross square footage and check the Covered Buildings List for energy laws.
- Count stories and units from the certificate of occupancy, not memory.
- Inventory equipment: boilers, elevators, tanks, backflow devices, gas service.
- Find your community district and tax block for gas piping, FISP and LL87 timing.
- Enter every due date in one calendar per building. Our compliance calendar has the fixed annual dates.
- Check open violations and know the difference between HPD and DOB violations.
If you own many small buildings rather than one large one, each address carries its own list. See managing a portfolio of small buildings.
How Yak helps
Yak Management is a principal-led Brooklyn property manager. Our specialty is rent-stabilized and subsidized housing and HPD compliance, and we manage buildings of 50 units and more alongside a portfolio of smaller ones.
For a fast first look, run the free Building Health Check. It pulls HPD violations, DOB and ECB violations, HPD registration and building size from public records and shows which local laws likely apply. You can also ask a principal for a full review. To see how we run larger buildings, read about management for 50+ unit buildings.